根據光學方式快速地做所有種類的液體檢測的可能!
因不需調整,不需很熟練就可安裝。
總成本是廉價高性能漏液感測器。
不僅是漏液,斷線或短路等的異常發生時在系統上也可檢測出。
通過從檢測部本身發出迅速特別指出漏液地方。
By optical detecting principle, most all kinds of liquid can be detected quickly.
No adjustment is required for the sensor, then very few risk for setting error Versatile on performance, and low cost on its expense for both of human and material.
Controller & Sensor, Available for many detected points
・The unique effects of optical method enable reliable detection of small leaks and viscous liquids.
・Relay contact Output signal makes it easy to construct the interlock function.
・Recommend RS-1000C and RS-1000 to customers particularly in case that there are many detected points.
■ RS-1000 Series Detection Unit
RS-1000F | RS-1000P | RS-1000FP | RS-1000PP | |||
---|---|---|---|---|---|---|
Supply Voltage | 5 VDC ±5% | |||||
Power Consumption | 20mA max | |||||
Indication of LED | Red: Leakage , Green: Normal | |||||
Ambienet Temperatur | -10~60 deg C (14~140 deg F) | |||||
Connection with Control Unit |
All Detection Unit must be used with RS-1000C or RS-1000CA Control Unit | |||||
Material | Case | PFA | PP | PFA | PP | |
Cable | FEP | HT-PVC | FEP | HT-PVC | ||
LED LAMP |
Epoxy (embedded) |
Epoxy (embedded) |
||||
Water Proofing | Sealed Silicon Stuffed |
Sealed Silicon Stuffed |
||||
Weight | Appx,50g | Appx,50g | ||||
Absorbent Paper | Required | Not Required | ||||
Selectable Bracket | P/N-6417, P/N-6418, P/N-6419 | P/N-6416, P/N-6420B |
■ RS-1000 Series Control Unit
RS-1000C | RS-1000CA | |
---|---|---|
Input Voltage | 5 VDC ±5% | |
Power Consumption | 150mA below | 200mA below |
Light of Leak Indicator (Red) | On: Leakage , Off: Normal | |
Relay Contact Output | NO contact x1 pole | NO contact x8 poles, independent |
Ambient Temperature | -60~60 deg C (14~140 deg F) | |
Capacity of Relay Contact (Max) | 24 VDC,1A (Resistance load) | |
Case Material | ABS polymer | |
Weight | Appx,90g | Appx,300g |
NPN Transistor Open collector. Internal Amplifier
・Fail Safe Design - Output current is conducted in normal dry conditions and will turn off in the presence of liquid.
・This liquid leak detector is suitable for the integrated monitoring and also individual monitor.
・This model can operate the load directly with its own output, without the RS-1000C Controller.
■ RS-1000*A Series Detection Unit
RS-1000FA -24V |
RS-1000PA -24V |
RS-1000FAP | RS-1000PAP | ||
---|---|---|---|---|---|
Supply Voltage | 5 - 24 VDC ±5% | ||||
Power Consumption | 20mA max | ||||
Indication of LED | Red: Leakage , Green: Normal | ||||
Ambient Temperature | -10〜60 deg C (14〜140 deg F) | ||||
Output | NPN Transistor Open Collector 50mA max, 2 opposite signals (Leakage - ON and Normal - ON) |
||||
Material | Case | PFA | PP | PFA | PP |
Cable | FEP | HT-PVC | FEP | HT-PVC | |
LED LAMP |
Epoxy (embedded) |
Epoxy (embedded) |
|||
Water Proofing | Sealed Silicon Stuffed |
Sealed Silicon Stuffed |
|||
Weight | Appx,50g | Appx,50g | |||
Absorbent Paper | Required | Not Required | |||
Selectable Bracket | P/N-6417, P/N-6418, P/N-6419 | P/N-6416, P/N-6420B |
By optical detecting principle, most all kinds of liquid can be detected quickly.
No adjustment is required for the sensor, then very few risk for setting error Versatile on performance, and low cost on its expense for both of human and material.
Quick Detection for variety of liquid. (NPN OUTPUT)
・ Quick Detection for variety of liquid, even low viscosity without absorbent paper.
・ By the featured double sensing devices, incorrect position of the sensor is alarmed.
・ Body fabricated by PFA, which allows use with most liquids and chemicals, and suitable for use in varied applications, particularly chemical blend and dispenser.
After leak detection, simple wipe the detection surface. much easier process than with detection tape or a liquid absorbing model.
・Body and cable are protected by PFA
・Suitable for export equipment, CE marking, UL certified.
・RS-3000C unit has DIN rail installation feature without auxiliary parts
・Easily viewable green LED signifies normal operations when red LED turns on, Liquid is detected and output is shut off.
■ RS-3000 Series Detection Unit
Model | RS-3000FA | RS-3000FAP | |
---|---|---|---|
Voltage | DC12V to DC24V (±10%) | ||
Current | 20mA or below | ||
LED Display | Normal Status : Green Leakage Alarm :Red Wrong position Alarm: Red |
||
Output | NPN transistor open collector, 50mA max, Normal: ON | ||
Ambient Temp | -10〜60℃ | ||
Material | Case | PFA | |
Cable | FEP, 3-wire sheath | ||
LED | Epoxy resin (embedded in the case) | ||
Water Protect | Sealed, Equivalent IP67(IEC) | ||
Weight | Approx. 40g | ||
Absorbent Paper | Use | Not Use | |
Bracket | P/N-6440(PVC) | P/N-6430(PVC) |
■ RS-3000 Series Control Unit
・Output of the control unit, RS-3000C is a relay, NC contact, which makes fit with fail-safe architecture.
・Compact in size of RS-3000C unit with connector wiring helps easier and reliable wiring job.
Model | RS-3000C |
---|---|
Voltage | DC24V(±10%) |
Current | 200mA or below |
Number of Input | 1 to 8 detection units max |
LED Display | Independent display for each Input (LED 8ea ×Green or Red either color) Normal status: Greed, Leakage or Wrong Position Alarm: Red |
Output | Relay contact × 1ea Normal status: Closed, Leakage or Wrong Position Alarm: Open, Power Failure: Open |
Output Capacity | DC24V,1A (resistance load) |
Ambient Temp | -10〜60℃ |
Case Material | ABS |
Weight | Approx. 100g |
Wiring Connection | Input: Connector × 8ea (insert - locked) Power/Output: Connector × 1ea (insert - locked) |
Installation | Snap-on DIN Rail, or screwed on the base plate. |
Detection Unit | RS-3000FA, RS-3000FAP |
Quick Detection for variety of liquid. (PNP OUTPUT)
・PNP model Developed for the U.S.A market
・It’s possible to use as the integrated monitor, which numerous Detectors connect to Control unit (RS-3500), or as the Alarm monitoring system, which numerous detect connect to PLC.
・Body of RS-3500 (Control Unit) also is fabricated by PFA, which allows use with most liquids and chemicals, and suitable for use in varied applications, particularly chemical blend and dispenser.
After leak detection, simple wipe the detection surface. much easier process than with detection tape or a liquid absorbing model.
・Body and cable are protected by PFA
・Suitable for export equipment, CE marking, UL certified.
・RS-3000C unit has DIN rail installation feature without auxiliary parts
・Easily viewable green LED signifies normal operations when red LED turns on, Liquid is detected and output is shut off.
■ RS-3500 Series Control Unit
Model | RS-3500FA | RS-3500FAP | |
---|---|---|---|
Voltage | DC12V to DC24V (±10%) | ||
Current | 20mA or below | ||
LED Display | Normal Status : Green Leakage Alarm :Red Wrong position Alarm: Red |
||
Output | PNP transistor open collector, 50mA max, Normal: ON | ||
Ambient Temp | -10〜60℃ | ||
Material | Case | PFA | |
Cable | FEP, 3-wire sheath | ||
LED | Epoxy resin (embedded in the case) | ||
Water Protect | Sealed, Equivalent IP67(IEC) | ||
Weight | Approx. 40g | ||
Absorbent Paper | Use | Not Use | |
Bracket | P/N-6440(PVC) | P/N-6430(PVC) |
■ RS-3500 Series Control Unit
・Output of the control unit, RS-3500C is a relay, NC contact, which makes fit with fail-safe architecture.
・Compact in size of RS-3500C unit with connector wiring helps easier and reliable wiring job.
Model | RS-3500C |
---|---|
Voltage | DC24V(±10%) |
Current | 200mA or below |
Number of Input | 1 to 8 detection units max |
LED Display | Independent display for each Input (LED 8ea ×Green or Red either color) Normal status: Greed, Leakage or Wrong Position Alarm: Red |
Output | Relay contact × 1ea Normal status: Closed, Leakage or Wrong Position Alarm: Open, Power Failure: Open |
Output Capacity | DC24V,1A (resistance load) |
Ambient Temp | -10〜60℃ |
Case Material | ABS |
Weight | Approx. 100g |
Wiring Connection | Input: Connector × 8ea (insert - locked) Power/Output: Connector × 1ea (insert - locked) |
Installation | Snap-on DIN Rail, or screwed on the base plate. |
Detection Unit | RS-3500FA, RS-3500FAP |
For the advanced performance is added to Standard Liquid Leak Sensor, RS-2000 series has self diagnostic function for alarming the electric failure or wiring error by short circuit or cut circuit, as realizing ‘Failsafe’ property to the system.
・RS-2000 detects liquid leak, also breaking of wire and short circuit. Then alarm.
・RS-2000 can provide superior safety system than RS-1000 by this diagnostic function.
■ RS-2000 Series Detection Unit
RS-2000F | RS-2000P | RS-2000FP | RS-2000PP | ||
---|---|---|---|---|---|
Supply Voltage | 5 DCV ±5% | ||||
Power Consumption | 20mA max | ||||
Indication of LED | Red: Leakage , Green: Normal , Off: Power Failure | ||||
Ambient Temperature | -10~60 deg C (14~140 deg F) | ||||
Connection with Control Unit |
All Detection Unit must be used with RS-2000C or RS-2000CA Control Unit | ||||
Material | Case | PFA | PP | PFA | PP |
Cable | FEP | HT-PVC | FEP | HT-PVC | |
LED LAMP |
Epoxy (embedded) |
Epoxy (embedded) |
|||
Water Proof | Sealed Silicon Stuffed |
Sealed Silicon Stuffed |
|||
Weight | Appx,50g | Appx,50g | |||
Absorbent Paper | Required | Not Required | |||
Selectable Bracket | P/N-6417, P/N-6418, P/N-6419 | P/N-6416, P/N-6420B |
■ RS-2000 Series Control Unit
RS-2000C | RS-2000CA | ||
---|---|---|---|
Input Voltage | 24 VDC ± 10% | ||
Power Consumption | 100mA below | 200mA below | |
Alarm Indication | LED for Leakage | Red: Leakage, Failure Off: Normal, Power Outage |
|
LED for Failure | Red: Failure Off: Normal |
||
Discrimination Detection | Yes | ||
Ambient Temp. | -10~60 deg C (4 ~ 140 deg. F) | ||
Number of Input for Detection Unit | 1 | 8 | |
Max Detection Unit per Input | 1 | ||
Relay Contact Outputs | Numbers | 1 | 9 (8 for Leakage, 1 for Failure) |
Capacity | 24VDC 1A max(resistance load) | ||
Status | Normal: Closed Leakage/Failure Alarm: Open Power Outage: Open |
||
Case Material | ABS Polymer | ||
Weight | 100g | 330g |
・Quick detection by spot where the liquid leakage occurs.
・RS-3000BZ is suitable for the large scale and complex factory.
・Alarm beep freeze when detection are taken out of Bracket.
・In a complex and large factory, “sound” saves time for locating.Where the leakage happens.
・All the same splendid features as those of RS-3000-BZ.
・RS-3500-BZ has been developed to propose PNP configuration circuit application, even. RS-3000-BZ is NPN configuration.
・RS-3500 matches with safety circuit design of zero voltage common grounded as PNP configuration is so.
・Using Control unit of RS-3500C, you can choose a neutral relay contact output. Furthermore RS-3500C provides a logically accumulated output from 8 input signal sources to one output, this is the same idea of RS-3000C.
These products are complied or adopted with the following overseas standard and restrictions.
Products Models | Category Control No. | File No. | ||
---|---|---|---|---|
Liquid Leak Sensor | ||||
RS-1000 Series | NRNT2 | Switches, Industrial Control | E176923 | Recognition |
RS-2000 Series | ||||
RS-3000 Series |
Products Models | CE Mark | LV Directives | EMC Directives | Machinery Directive |
---|---|---|---|---|
Liquid Leak Sensor | ||||
RS-1000 Series | Marked | Not Applied | Complied | — |
RS-2000 Series | ||||
RS-3000 Series |
RS-1000、-2000、-3000 Series are able to comply with EU-RoHS ( Restricted 6 Substances). For details, please contact us.